Temperature transmitter with digital adjustment, -30/+100°C
Measuring Range: -30,0 ... +100,0°C (Standard), others on request
The probe length has to be choosen long enough, that the allowable
temperature range of the electronics, located in the cable sleeve, is not
exceeded.
Sensor: internal Pt1000 sensor
Accuracy Electronic: ±0,2% of reading ±0,2°C
Accuracy Sensor: DIN class B
Output Signal: 4...20mA, 2 wire
Auxiliary Power: 10 ... 30VDC
Working Temperature Electronic: -25 ... +60°C
Housing: stainless steel
Cable Sleeve: Ø15 x 35mm (without screwing)
Probe Length: FL = 100mm (other on customer requirement)
Thread: G1/2" (Standard)
possible threads: M8x1, M10x1, M14x1.5, G1/8", G3/8", G3/4"
Probe Diameter: D=6mm (Standard),
possible Ø: 4, 5, 6 und 8mm
Scaling: The transmitter can be scaled freely within the measuring ranges via
GTMU-IF programming tool