Standard-jacket-thermo-element, type K GTF101-5
Sensor diameter D: 1.5 mm;
Insertion length: 250 mm
A tube with Ø 1.5 mm slim piercing tip, small Teflon handle, stainless steel kink protection, 1 m Teflon cable, 4-pin mini DIN plug.
Response time T90:
Water 0.4 m/s <1 s, Air 2 m/s approx. 12 s.
HIGHLIGHTS:
High temperature and pressure resistance
Resistant to aggressive atmosphere
very small dimensions possible and therefore short response times
bendable (smallest bending radii with small diameters possible)
potential-free (thermocouple wires have no connection to the outer sheath)
highest accuracy class 1 according to DIN IEC584
TECHNICAL DATA:
Sheath material:
Inconel 600, bendable (standard),
insulation:
highly compressed pure MgO
Thermocouple wires:
NiCr-Ni, DIN IEC 584, insulated welded (potential free)
Accuracy:
highest accuracy class (cl. 1) = ±1.5 °C or ±0.4 % of measured value.
(Compared to class 2 e.g. almost double accuracy.
For comparison: class 2: ±2.5 °C resp. ±0.75 % of MW.)
Connection cable:
Silicone compensating cable, 1 m long (max. 200 °C), loose ends.
Temperature application range:
-200 ... +1150 °C
(probe tip or front part; cable sleeve up to max. 200 °C, cable see accessories) (accuracy class 1 valid from -40 ... +1000 °C)
Recommended upper temperature limit for continuous use:
Ø 0,5 1,0 1,5
°C 700 700 920