Monday, 11. December 2017 
 
     

    Enter search term(s)
  N o v e l t i e s Show products: 40 50 All  
 Prices 
 


Product Information
Instruction Manual
GLMU 200 MP-TR
Conductivity measuring transducer incl. 2-pole measuring cell

General:
2-pole measuring cells, suitable for use in clean / potable / fresh water
Recommended usage range: up to 2000 µS/cm
4 Measuring ranges: 0.1 µS/cm ... 200.0 mS/cm

Measuring cell LFE 202
Ø 12 mm 2-pole
Graphite,
C=1.0;
-5 ... +80 °C

Price info


Product-ID: 607814

 
 


Product Information
Instruction Manual
GLMU 400 MP-UNI-AV420
Conductivity measuring transducer

Transmitter without measuring cell, suitable for 2- and 4-pol. measuring cells to create your own conductivity measuring system with special measuring cells.

Output signal 4-20 mA

Note:
The measuring accuracy of the overall system strongly depends from the measuring cell used and the area of application

Price info


Product-ID: 608052

 
 


Product Information
Instruction Manual
GLMU 200 MP-TR-PG
Conductivity measuring transducer incl. 2-pole measuring cell

General:
2-pole measuring cells, suitable for use in clean / potable / fresh water
Recommended usage range: up to 2000 µS/cm
4 Measuring ranges: 0.1 µS/cm ... 200.0 mS/cm

Measuring cell LFE 202-PG
Ø 12 mm 2-pole
Graphite,
C=1.0;
-5 ... +80 °C

Price info


Product-ID: 607815

 
 


Product Information
Instruction Manual
SoilTemp 285
Soil thermometer

Features:
The universal display device combined with an extremely robust, but yet ergonomic T-handle probe made of stainless steel allows for multiple measurements in soils or bulk materials.
Application:
Silo checking, measurements in soils, waste dumps, silages, compost, etc. The alarm function additionally allows for acoustic monitoring of the selected temperature boundaries.

Specifications:
Device: GMH 285-BNC
Probe connection: BNC, Pt1000, 2-wire
Measuring range: -50.0 ... +250.0 °C
Measuring rod: Stainless steel, 1000 mm x Ø 10 mm, 1 m connection cable with BNC plug, 350 g, probe handle designed for comfortable use
Scope of supply: GMH 285-BNC, GTF 40 T, battery, manual

Price info


Product-ID: 605849

 
 


Product Information
Instruction Manual
GMH 285-BNC
Alarm thermometer with BNC socket

Features:
High precision, alarm, backlight and many other features characterize this device as a true all-rounder. The alarm function additionally allows for acoustic monitoring of the set temperature boundaries.
Application:
Highly accurate measurements over a large measuring range in liquids, soft media, air/gases. Used for e.g. measurement in agriculture, quality control, laboratory, food production, etc.

Specifications:
Measuring range: -200.0 °C ... 400.0 °C or -200.0 °F ... 752.0 °F
Resolution: 0.1 °C or 0.1 °F
Dimensions: 142 x 71 x 26 mm (H x W x D)
Weight: approx. 170 g (incl. battery)

Price info


Product-ID: 605507

 
 


Product Information
Instruction Manual
datasheet
G 1730
Precise universal thermometer with permanently connected insertion sensor, Ø 1.5 mm

Application:
The highest-precision measurements in liquids and in air, for measurement of core temperatures (with insertion sensor); sensor handle and cable temperature range of up to 250 °C (permanent use temperature of 230 °C); laboratories, quality assurance, service, food, etc.

 

Specifications:
Measurement range: -70.0 ... +250.0 °C (-94.0 ... +482.0 °F)
Accuracy: (at nominal temperature = 25 °C)
-20 ... +100 °C: ±0.1 K ±1 digit, -70 ... +250 °C: ±0.2 % of m. v. ±2 digits
Sensor: Extra-thin insertion sensor Ø 1.5 mm, Pt1000 permanent 2-wire connection, V4A, 1 m cable
Scope of supply: Device with integrated sensor, calibration log, 2 x battery, operating manual

Price info


Product-ID: 609832

 
 


Product Information
GTF 112                                                                                                                 from
Temperature probe

Temperature range: -50 … +250 °C (probe tip)

General:
The GTF 112 is a temperature sensor with threaded process with a practical M12 connector.
The measurement is performed by means of resistance temperature sensors Pt100 or Pt1000.

 

 

 

not available via online-shop, ordering code is deposited at product information,
please order via mail info@greisinger.de

Price info


Product-ID: 999911

 
 


Product Information
Instruction Manual
GMH 5650
Oxygen Meter for Dissolved Oxygen in liquids with data logger

General:

  • Waterproof and robust
  • Display backlight
  • Automatic ambient pressure compensation with integrated precision barometer

Application:

  • Oxygen monitoring in aqua culture and aquarisitcs
  • Checking of well water, waste water, sewage treatment plants

Specification:
 
Measuring ranges: (device)

   Oxygen concentration: 0.00 ... 70.00 mg/l (ppm) (selectable)
   Oxygen saturation: 0.0 ... 600.0 % O2 (selectable)
   Oxygen partial pressure: 0 ... 1200 hPa O2 (0.0 ... 427.5 mmHg)
   Temperature: 0.0 ... 50.0 °C
   Pressure: 300 ... 5000 hPa abs., 0 … 40.0 m water column

Dimensions:  160 x 86 x 37 mm (L x W x H) incl. silicone protective cover,
                        pressure connection: length 11 mm
Weight: approx. 250 g device incl. battery and cover
Scope of supply: Handheld instrument, battery, manual, short form manual

     

    Price info


    Product-ID: 606882

     
     


    Product Information
    Instruction Manual
    GIR 300-G24
    Universal displaying and controlling device with electrically isolated supply
    • Universal input for standard signals, frequency, Pt100, Pt1000 and thermocouples
    • 2 integrated switching outputs (electrically isolated)
    • Configurable as display or controller (5 switching functions)
    • Fast controlling and monitoring

    Specifications:

    Measuring and display range, resolution:
    Temperature: (unit switchable between °C and °F)
    Pt100: -200 ... +850 °C or -50,0 ... +200,0 °C;
    Pt1000: -200 ... +850 °C;
    Type J: -170 ... +950 °C;
    Type K: -270 ... +1350 °C;
    Type N: -270 ... +1300 °C;
    Type S: -50 ... +1750 °C;
    Type T: -270 ... +400 °C
    Standard signals: -1999 ... 9999 digit, decimal point, start and end value freely selectable, recommanded range: ? 2000 digit
    Frequency: 0.000 Hz ... 10 kHz, display freely scalable
    Rotational speed: 0.000 U/min ... 9999 U/min, selectable prescaler: 1-1000
    Up- / down- counter: The counter reading is stored also in power-down state. 0 ... 9999 (10 million with prescaler),
    pulse frequency: ? 10 kHz, selectable prescaler: 1-1000
    Serial interface: Display and control functions with values obtained via serial interface
    Supply voltage: 22 ... 27 V DC, electrically isolated
    Housing: Dimensions: 36 x 72 mm (front frame), Installation depth: approx. 75 mm (incl. screw-type/plug-in terminals)
    Scope of supply: device, manual

    Price info


    Product-ID: 605203

     
     


    Product Information
    Instruction Manual
    GMH 285-KB
    Alarm thermometer with 3.5 mm jack socket

    Features:
    High precision, alarm, backlight and many other features characterize this device as a true all-rounder. The alarm function additionally allows for acoustic monitoring of the set temperature boundaries.
    Application:
    Highly accurate measurements over a large measuring range in liquids, soft media, air/gases. Used for e.g. measurement in agriculture, quality control, laboratory, food production, etc.

    Specifications:
    Measuring range: -200.0 °C ... 400.0 °C or -200.0 °F ... 752.0 °F
    Resolution: 0.1 °C or 0.1 °F
    Dimensions: 142 x 71 x 26 mm (H x W x D)
    Weight: approx. 170 g (incl. battery)

    Price info


    Product-ID: 605506

     
     


    Product Information
    Instruction Manual
    GMH 1170-Basic-SET
    Universal Temperature Measuring Set

    Temperature measuring set ready-for-use with insertion probe, wire probe and case.

    Scope of supply:
    GMH 1170, GTF 300, GES 900, GKK 1105

    Price info


    Product-ID: 605414

     
     


    Product Information
    Instruction Manual
    GMH 3511
    pH / ORP / temp. measuring device

    Specification:

    Measuring ranges: 
       Temperature: -5.0 ... +150.0 °C or 23.0 ... +302.0 °F
       pH: 0.00 ... 14.00 pH
       Redox (ORP): -1999 ... +2000 mV
                            Based on hydrogen system: -1792 ... +2207 mVH (DIN38404)
    Accuracy (device): ±1 digit at nominal temperature = 25 °C
       Temperature: ±0.2 °C (at range -5 ... 100 °C)
       pH: ±0.01 pH
       Redox (ORP): ±0.1% FS (mV or mVH)
    Dimensions: 142 x 71 x 26 mm (H x W x D)
    Weight: approx. 170 g
    Scope of supply: Device, battery, manual

    Price info


    Product-ID: 604953

     
     


    Product Information
    Instruction Manual
    GMH 5690
    Waterproof air oxygen measuring device without sensor

    Application:
    Protective gas measurements for
    - Welding and soldering
    - Food production/packaging technology (MAP, see also the GHM 5690 GOG Set)
    - For storage of foods, semiconductor components, etc.
    - Immersion gas testing: Checking of oxygen concentration in nitrox, trimix or similar gas
    compositions
    Note: Not suitable for use in 'underwater applications' (rebreather, etc.)

    Specifications:
    Measuring channels: O2, T, air pressure (integrated )
    Measuring ranges:
    O2 concentration: 0.0 … 100.0 % O2 Vol. or 0.00 … 100.00 % O2 Vol. (resolution can be selected in menu)
    O2 partial pressure: 0 … 1100 hPa O2 / 0 … 825 mmHg O2, 0.0 … 1100.0 hPa O2 / 0.0 … 825.0 mmHg O2 (resolution can be selected in menu)
    Temperature: -5.0 ... +50.0 °C
    Air pressure: 10 ... 1200 hPa abs
    Accuracy: (device at nominal temperature = 25 °C)
    O2 concentration: ±0.1 % ± 1 digit
    Temperature: ±0.1 °C ± 1 digit
    Air pressure: ±3 hPa or 0.1 % of MW (higher applies)

    Dimensions: 160 x 86 x 37 mm (H x W x D) including protective silicone case
    Weight: approx. 250 g, including battery and protective case
    Scope of supply: Handheld measuring device incl. batteries (2xAAA), protective silicone case, manual, quick guide

    Price info


    Product-ID: 607466

     
     


    Product Information
    Instruction Manual
    GE 114-BNC
    pH-elektrode with BNC-plug

    Measuring range: 0 ... 14 pH, 0 ... 60 °C
    Conductivity: > 200 µS / cm
    Cable: 1 m
    Electrolyte: gel electrolyte
    Diaphragm: 1 x pellon
    Electrode shaft: epoxide, Ø 12 mm x 120 mm
    Features: Low-cost, low-maintenance

    Electrodes are consumption objects.
    Lifetime under careful treatment: > 2 years; warranty: 12 months

    Price info


    Product-ID: 604701

     
     


    Product Information
    Instruction Manual
    datasheet
    G 1720
    Precise universal thermometer with permanently connected insertion sensor, Ø 3 mm

    Application:
    The highest-precision measurements in liquids and in air, for measurement of core temperatures (with insertion sensor); sensor handle and cable temperature range of up to 250 °C (permanent use temperature of 230 °C); laboratories, quality assurance, service, food, etc.

     

    Specifications:
    Measurement range: -70.0 ... +250.0 °C (-94.0 ... +482.0 °F)
    Accuracy: (at nominal temperature = 25 °C)
    -20 ... +100 °C: ±0.1 K ±1 digit, -70 ... +250 °C: ±0.2 % of m. v. ±2 digits
    Sensor: Durable insertion sensor Ø 3 mm, Pt1000 permanent 2-wire connection, V4A, 1 m cable
    Scope of supply: Device with integrated sensor, calibration log, 2 x battery, operating manual

    Price info


    Product-ID: 609829

     
     


    Product Information
    Instruction Manual
    datasheet
    G 1710
    Precise universal thermometer with permanently connected immersion sensor, Ø 3 mm

    Application:
    The highest-precision measurements in liquids and in air, for measurement of core temperatures (with insertion sensor); sensor handle and cable temperature range of up to 250 °C (permanent use temperature of 230 °C); laboratories, quality assurance, service, food, etc.

     

    Specifications:
    Measurement range: -70.0 ... +250.0 °C (-94.0 ... +482.0 °F)
    Accuracy: (at nominal temperature = 25 °C)
    -20 ... +100 °C: ±0.1 K ±1 digit, -70 ... +250 °C: ±0.2 % of m. v. ±2 digits
    Sensor: Immersion sensor Ø 3 mm, Pt1000 permanent 2-wire connection, V4A, 1 m cable
    Scope of supply: Device with integrated sensor, calibration log, 2 x battery, operating manual

    Price info


    Product-ID: 609828

     
     


    Product Information
    Instruction Manual
    GGA 380
    Atmospheric oxygen sensor

    Pressure connection, suitable for GMH 369x

    General:
    For devices with external pressure port (GMH 3695) is this housing optimal.
    Especially for systems with high or low pressure or with existing back pressure by fl ow.

    Application:
    It can be screwed airtight (Attention: Observe permissible operating pressure!). The
    device-pressure port is connected to the sensor pressure port. The device measures and
    compensates for the actual pressure at the sensor.

    longer cable length 4 m and 10 m on demand

    Price info


    Product-ID: 607485

     
     


    Product Information
    Instruction Manual
    GMH 5630
    Oxygen Meter for Dissolved Oxygen in liquids

    General:

    • Waterproof and robust
    • Display backlight
    • Automatic ambient pressure compensation with integrated precision barometer

    Application:

    • Oxygen monitoring in aqua culture and aquarisitcs
    • Checking of well water, waste water, sewage treatment plants

    Specification:

    Measuring ranges: (device)
       Oxygen concentration: 0.00 ... 70.00 mg/l (ppm) (selectable)
       Oxygen saturation: 0.0 ... 600.0 % O2 (selectable)
       Oxygen partial pressure: 0 ... 1200 hPa O2 (0.0 ... 427.5 mmHg)
       Temperature: 0.0 ... 50.0 °C
       Pressure: 10.0 ... 1200.0 hPa abs


    Dimensions:  160 x 86 x 37 mm (L x W x H) incl. silicone protective cover
    Weight: approx. 250 g device incl. battery and cover
    Scope of supply: Handheld instrument, battery, manual, Short form manual

       

      Price info


      Product-ID: 606880
       


      Product Information
      Instruction Manual
      GWO 5610-L02
      Sensor with 2 m cable
      General:
      Standard, for laboratory use, electrode is delivered filled,
      dry delivery available on request
      Price info


      Product-ID: 607386

       
       


      Product Information
      Instruction Manual
      GIR 360
      Universal counter and frequency meter

      Specifications:
      Inputs:
      Input 1: frequency, rotational speed, counter input A
         Input voltage: 0 ... 5 V (0 ... 28 V with dropping resistor)
         Input level: Low < 0.5 V; High > 2.2 V
         NPN: pullup resistor 7 kohms to 3.3 V
         PNP: pulldown resistor 7 kohms against GND
         Min. pulse width: 50 us
      Input 2: count input B, Gate, direction
         Input voltage: 0 ... 5 V (0 ... 28 V with dropping resistor)
         Input level: Low < 0.5 V; High > 2.2 V
         NPN: pullup resistor 7 kohms to 3.3 V
         PNP: pulldown resistor 7 kohms against GND
         Min. pulse width: 50 us
      Input 3: reset input
         Input level: Low < 1 V; High > 8 V
         Min. pulse width: 50 ms
      Measuring / counting areas:
         Frequency: 0 ... 10 kHz
         Speed: max. 10000 U/min, switchable prescaler: 1 ... 1000
         Counter: -2.147.483.647 … 2.147.483.646
      Supply voltage: 9 ... 28 V DC (standard)
      Scope of supply: device, manual

      Price info


      Product-ID: 607953

       
       


      Product Information
      Instruction Manual
      GIR 360-G24
      Universal counter and frequency meter

      Specifications:
      Inputs:
      Input 1: frequency, rotational speed, counter input A
         Input voltage: 0 ... 5 V (0 ... 28 V with dropping resistor)
         Input level: Low < 0.5 V; High > 2.2 V
         NPN: pullup resistor 7 kohms to 3.3 V
         PNP: pulldown resistor 7 kohms against GND
         Min. pulse width: 50 us
      Input 2: count input B, Gate, direction
         Input voltage: 0 ... 5 V (0 ... 28 V with dropping resistor)
         Input level: Low < 0.5 V; High > 2.2 V
         NPN: pullup resistor 7 kohms to 3.3 V
         PNP: pulldown resistor 7 kohms against GND
         Min. pulse width: 50 us
      Input 3: reset input
         Input level: Low < 1 V; High > 8 V
         Min. pulse width: 50 ms
      Measuring / counting areas:
         Frequency: 0 ... 10 kHz
         Speed: max. 10000 U/min, switchable prescaler: 1 ... 1000
         Counter: -2.147.483.647 … 2.147.483.646
      Supply voltage: 22 ... 27 V DC, electrically isolated
      Scope of supply: device, manual

      Price info


      Product-ID: 607954

       
       


      Product Information
      Instruction Manual
      GMH 5695
      Waterproof air oxygen measuring device without sensor with data logger and alarm

      Application:
      Protective gas measurements for
      - Welding and soldering
      - Food production/packaging technology (MAP, see also the GHM 5690 GOG Set)
      - For storage of foods, semiconductor components, etc.
      - Immersion gas testing: Checking of oxygen concentration in nitrox, trimix or similar gas
      compositions
      Note: Not suitable for use in 'underwater applications' (rebreather, etc.)

      Specifications:
      Measuring channels: O2, T, air pressure (integrated with external connection)
      Measuring ranges:
      O2 concentration: 0.0 … 100.0 % O2 Vol. or 0.00 … 100.00 % O2 Vol. (resolution can be selected in menu)
      O2 partial pressure: 0 … 1100 hPa O2 / 0 … 825 mmHg O2, 0.0 … 1100.0 hPa O2 / 0.0 … 825.0 mmHg O2 (resolution can be selected in menu)
      Temperature: -5.0 ... +50.0 °C
      Air pressure: 300 ... 5000 hPa abs
      Accuracy: (device at nominal temperature = 25 °C)
      O2 concentration: ±0.1 % ± 1 digit
      Temperature: ±0.1 °C ± 1 digit
      Air pressure: ±3 hPa or 0.1 % of MW (higher applies)

      Dimensions: 160 x 86 x 37 mm (H x W x D) including protective silicone case
      Weight: approx. 250 g, including battery and protective case
      Scope of supply: Handheld measuring device incl. batteries (2xAAA), protective silicone case, manual, quick guide

      Price info


      Product-ID: 607468

       
       


      Product Information
      Instruction Manual
      GLMU 400 MP-UNI-AV01
      Conductivity measuring transducer

      Transmitter without measuring cell, suitable for 2- and 4-pol. measuring cells to create your own conductivity measuring system with special measuring cells.

      Output signal 0-1 V

      Note:
      The measuring accuracy of the overall system strongly depends from the measuring cell used and the area of application

      Price info


      Product-ID: 608053

       
       


      Product Information
      Instruction Manual
      GMH 5430
      Water-proof conductivity handheld device, without electrode

      Features:

      • Water-proof (device and plug-in connections)
      • Serial intervace
      • Average filter
      • Silicone protection cover
      • Large double display
      • Background illumination

      Application:

      • Industry and craft
      • Measurements of waters and aquaristics
      • Fish farming
      • Drinking water monitoring, process control, soil measruements
      • Food production and control
      • Quality management
      • Additional applications at laboratory:
        medicine, pharmacy, chemistry

      Specification:

      Number of measuring ranges:

      5
      Connection:
         Electrode 1x 7-pole bayonet socket (Conductivity and Temperature)

         Interface /
        
      ext. supply

      4-pole socket for serial interface and supply (with accessories: USB adapter USB 5100)
      Display:        two 4½-digit 7-segment display (15 mm and 12 mm)

      Price info


      Product-ID: 600035

       
       


      Product Information
      Instruction Manual
      GMH 3692
      Air oxygen measuring device w/o sensor

      Application:

      • Bio chemistry: Oxygen monitoring in breeding chambers for cell cultures. Monitoring of fermenting process of fruits in fermentation plants etc.
      • Medicine: Monitoring of oxygen concentration in respirators; checking of breathing, monitoring of oxygen concentration in incubators, oxygen tents etc.
      • Food technology: Monitoring of residual oxygen in packages (e.g. coffee, tea, etc.).
        Monitoring of oxygen content during production processes.
      • Air conditioning and ventilation technology: Oxygen measurements, air quality monitoring, measuring of oxygen concentration in enclosed air conditioning systems, etc.
      • Sport: Checking of oxygen content in compressed air bottles (diving, etc.).

      Specification:
      Measuring ranges: 
         Oxygen concentration: 0.0 ... 100.0 % O2 (gaseous), 0 ... 1100 hPa O2
         Temperature: -5.0 ... 50.0 °C
         Air pressure: 10 ... 1200 hPa
      Dimensions: 142 x 71 x 26 mm (H x W x D)
      Weight: approx. 160 g (incl. battery)
      Scope of supply: Device, battery, manual

      Price info


      Product-ID: 605919
       


      Product Information
      Instruction Manual
      BaleCheck 200
      Hay and straw humidity measuring device with temperature measuring

      Professional set for humidity and temperature
      measurements in pressed bales of hay and straw

      Features

      • Practical and robust
      • Humidity display in percent
      • Visual humidity rating
      • Specific characteristics for hay and straw, barley, wheat, reference curve for comparison measurement e.g. in silage
      • Fast temperature measuring in probe tip

      Applications

      • Agriculture
      • Hay and straw processing / stocking 
      • Hay and straw trading 
      • Cattle breeding 
      • Horse keeping 
      • Fire prevention 
      •  …

       Specifications:

      Measuring range:

      Water content (w): 0,0 … 50%
      Material moisture (u): 0,0 … 100%
      Temperature (Type K): -0,0 … 100,0°C
      (Measuring range handheld -40,0 ... 200,0 °C)

      Characteristics

      Hay, straw, barley, wheat, reference curve

      Humidity rating:

      9-stage bar graph (wet … dry)

      Device:

      Probe:
      Cable:

      Impact-resistant ABS, dimensions:  142 x 71 x 26 mm
      (H x W x D), weight: 155 g
      Stainless steel, length: 600 mm, Ø: 10 mm, weight: 260 g Fixed to probe, BNC- & thermoelement plug, length: 1 m

      Power supply:

      9 V block battery (type 6F22, included in scope of delivery)

      Feature:

      Visual moisture rating, hold function, Auto-Power-Off incl. protection bag

      Scope of supply:

      device, measuring rod with temperature sensor,
      protective bag, operation manual

      Price info


      Product-ID: 600354

       
       


      Product Information
      Instruction Manual
      GTH 200 air
      Präzisions-Raumthermometer

      fast and precise temperature measurements in:

      • calibration rooms
      • production / computer rooms
      • living space
      • laboratories
      • etc.

      Specifications:

      Measuring range: -25.0 ... +70.0 °C
      Resolution: 0.1 °C
      Accuracy: (±1 digit) (at nominal temperature) ± 0.5% of meas. value ±0.1 °C
      Sensor: Pt 1000, 1/3 DIN class B

      Price info


      Product-ID: 600251

       
       


      Product Information
      Instruction Manual
      GMH 2710-F
      One-handed Temperature measuring device incl. insertion probe

      Ideal for measurements at hard-to-reach areas, i. e.

      • Stock-Temperature-Control (part. food)
      • HACCP
      • incoming goods inspection
      • Temperature measurements during the legionellae tests.

      Specification:
      Measuring range: -70 ... +250 °C
      Resolution: 0.1 °C
      Accuracy:
      at -20.0 ... 100.0 °C:  ±0.1 °C ±1 digit
      at -70.0 ... 200.0 °C: ±0.1 % of meas. value ±2 digit
      sensor calibrated together with device
      Probe: V4A jacket tube, flexible, diameter: 3 mm / length: 150 mm
      Response Time T90: approx. 10 s
      Display: two 4-digit LCD (12,4 mm and 7 mm)

      Price info


      Product-ID: 604035

       
       


      Product Information
      AirCheck 100
      Indoor climate monitoring, CO2 monitoring
      • large CO2 displaying
      • high long-term stability
      • air quality rating GOOD / NORMAL / POOR
      • humidity / temperature display, real-time clock, calendar
      • alarm function

      Application:

      • training, conference and break rooms
      • housing rooms
      • offices, laboratories
      • public buildings, schools, etc.

      Measuring range:
         CO2:
         Temperature:
         Humidity:

       
      0 … 2000 ppm
      -10 °C … +60 °C
      5,0 … +90,0 % r.F.

      Resolution::
         CO2:
         Temperature:
         Humidity:

      1 ppm
      0,1 °C / 0,1 °F
      0,1 % r.F.

      Accuracy:
         CO2:
         Temperature:
         Humidity:


      50 ppm ± 5 % of meas. value
      ± 0,6 °C
      ± 5 % r.F (@25 °C, 10-90 % r.F.)
      ± 7 % r.F (@25 °C, <10 % r.F., > 90 % r.F.)

      Alarm:

      > 1000 ppm (adjustable)
      acoustically: buzzer, 80 dB
      visually: ventilator symbol displayed

      Scope of supply:

      1 device, 1 power supply unit, 1 operation manual

      Price info


      Product-ID: 118930

       
       


      Product Information
      Instruction Manual
      Operating Manual
      GOO 380
      Atmospheric oxygen sensores

      for low oxigen-concentration, fast response time, suitable for GMH 369x

      General:
      • suitable for air- or gas-stream
      • quick temperature compensation

      Application:
      Because of the special sensor construction the measuring gas streams optimally around
      the sensor and escapes through holes in the housing into the air. No pressure build-up at
      slight streaming of the probe, that falsify the result of measurement. Particularly suitable
      for measuring of gas out of gas-bottle etc. Even measuring indoor-gas concentration is
      possible.

      longer cable length 4 m and 10 m on demand

      Price info


      Product-ID: 601230

       
       


      Product Information
      Instruction Manual
      datasheet
      G 1700
      Precise thermometer, BNC socket, without probe

      Application:
      The highest-precision measurements in liquids and in air, for measurement of core temperatures (with insertion sensor); sensor handle and cable temperature range of up to 250 °C (permanent use temperature of 230 °C); laboratories, quality assurance, service, food, etc.

       

      Specifications:
      Measuring range: -200.0 … +450.0 °C (-328.0 ... +842.0 °F) - Observe the allowed range of application for the probe!
      Accuracy: (at nominal temperature = 25 °C) -20 ... +100 °C: ±0,1 K ±1 digit, else 0.1 % v.MW ±2 digit
      Scope of supply: Device, Calibration protocol, 2 x battery, manual

      Price info


      Product-ID: 609826

       
       


      Product Information
      Instruction Manual
      GMH 2710-G
      Temperature measuring device incl. mini Teflon probe

      Application:
      Accurate measurements for laboratories, quality management, and monitoring of production processes

      Area of application:
      Food (HACCP), medical / pharmaceutical science, chemistry, aquaristics, fish farming, aquaculture, etc.

      Specification:
      Measuring range: -199.9 ... +250.0 °C
      Accuracy:
      0.1 °C
      Genauigkeit: at -20,0 ... 100,0 °C:  ±0.1 °C ±1 digit 
                           at -70,0 ... 200,0 °C: 
      ±0.1 % of meas. value ±2 digit
                           sensor calibrated togehter with device
      Probe: 
      design type with small Teflon handle and 1 m Teflon cable, with slim insertion tip, handle and cable are suitable for permanent application at temperatures up to 250 °C. Stainless steel kink protection, Ø 1.5 mm / length: 100 mm
      Response time T90: approx. 10 s
      Display: two 4-digit LCD (12.4 mm and 7 mm)

      Price info


      Product-ID: 602040

       
       


      Product Information
      Instruction Manual
      GGA 580
      Atmospheric oxygen sensor

      Pressure connection, suitable for GMH 569x

      General:
      For devices with external pressure port (GMH 5695/3695) is this housing optimal.
      Especially for systems with high or low pressure or with existing back pressure by fl ow.

      Application:
      It can be screwed airtight (Attention: Observe permissible operating pressure!). The
      device-pressure port is connected to the sensor pressure port. The device measures and
      compensates for the actual pressure at the sensor.

      longer cable length 4 m and 10 m on demand

      Price info


      Product-ID: 607487

       
       


      Product Information
      Instruction Manual
      GGA 570
      Atmospheric oxygen sensor

      Pressure connection, suitable for GMH 569x

      General:
      For devices with external pressure port (GMH 5695/3695) is this housing optimal.
      Especially for systems with high or low pressure or with existing back pressure by flow.

      Application:
      It can be screwed airtight (Attention: Observe permissible operating pressure!). The
      device-pressure port is connected to the sensor pressure port. The device measures and
      compensates for the actual pressure at the sensor.

      longer cable length 4 m and 10 m on demand

      Price info


      Product-ID: 607486

       
       


      Product Information
      Instruction Manual
      GGA 370
      Atmospheric oxygen sensor

      Pressure connection, suitable for GMH 369x

      General:
      For devices with external pressure port (GMH 3695) is this housing optimal.
      Especially for systems with high or low pressure or with existing back pressure by fl ow.

      Application:
      It can be screwed airtight (Attention: Observe permissible operating pressure!). The
      device-pressure port is connected to the sensor pressure port. The device measures and
      compensates for the actual pressure at the sensor.

      longer cable length 4 m and 10 m on demand

      Price info


      Product-ID: 607484

       
       


      Product Information
      ResOx 5695-L
      Residual oxygen measuring system (with recommended sensor element GOEL 381)

      General:
      New measuring system with gas pump for more measuring comfort - can now also be
      used in rigid packages and packages with low quantities of gas.

      Application:
      Quality control for MAP food packaging and comparable applications

      Specifications:
      Measuring channels: O2, T, air pressure
      Measurement ranges
      O2: 0.0 … 100.0 % O2 or displayed in hPa O2 / mmHg O2
      Temperature: 0.0 … 50.0 °C
      Air pressure: 300 … 5000 hPa (Sensor: 500 ... 2000 hPa)
      Additional functions: Min / max function – for comfortable measurement of the limit value
      Pressure compensation in the gas path – negative pressure in the package / on the sensor is compensated for
      Scope of supply: Ready-to-operate system: Display GMH 5695, incl. battery, sensor housing with pressure connection, incl. sensor, gas pump GS 150, incl. battery, connection lines, hoses/T-piece,
      2 GDZ 29 fi lters, 2 GOG-N puncture needles Ø 0.9 mm, 1 GOG-B: 45 pcs. adhesive seal, carry case GKK 1420

      Price info


      Product-ID: 610041

       
       


      Product Information
      Instruction Manual
      Application areas: Electrodes
      GE 104 Cinch
      pH electrodes with Cinch connection

      Measuring range: 2 ... 14 pH and 0 - 80 °C
      Conductivity:
      20 µS
      Electrolyte:
      3 mol/l KCL
      Miscellaneous: 1 m cable, BNC-plug
      Features: for low-ion media
      Application areas: emulsions, fish farming, low-ion media, cosmetics, sea water, suspensions, drinking water, water-based lacquers

      Price info


      Product-ID: 604504

       
       


      Product Information
      Instruction Manual
      GMH 3531
      pH / ORP / temperature measuring device

      Measuring range Temperature: -5.0 ... +150.0 °C or 23.0 ... +302.0 °F
      Measuring range pH: 0.00 ... 14.00 pH
      Measuring range redox (ORP): -1999 ... 2000 mV
      Measuring range rH: 0.0 ... 70.0 rH
      Sensor connection temperature:
      2 x 4 mm banana socket for Pt1000, 2-wire
      Sensor connection pH/redox: BNC socket

      automatic temperature compensation:
      In operation mode „pH“ an automatic temperature compensation (ATC) is possible in the range 0 ... 105 °C if a temperature probe is connected. Otherwise a manual input of temperature is possible.

      pH calibration:
      The buffer type is automatically detected. The temperature dependency of the buffer is automatically compensated.

      ORP measurement (redox):
      There are 2 choices:
      „mV": standard ORP or mV measurement
      „mV
      H"
      : temp. compensated conversion to hydrogen system acc. to DIN38404 part 6, table 1 based on the standard ORP electrode (e.g. GE105 with Ag/AgCl system and 3 mol KCl) used.

      rH measurement:
      Calculation of the rH value by means of a ORP measurement and by manually entering the pH-value. The pH-value may also be taken from a previous pH measurement.


      Functions: Min / max value memory, Hold function, Automatic off function, battery change indicator
      Scope of supply: device, battery, manual

      Note:
      w/o accessories, please order pH-probe and calibration accessories (i.e. GAK1400) separately

      Price info


      Product-ID: 602076

       
       


      Product Information
      Instruction Manual
      GMH 3181-002
      Feinest manometer with Data logger for over/under pressure and pressure difference

      Description:

      with integrated absolute pressure sensor
      Suitable for air and non aggressive gas

      Specification:

      Measuring range: -5000 ... +500.0 Pa (-5.000 ... +5.000 mbar)
      Overload:
      max. 250 hPa (mbar)
      accuracy (typ. values): ± 0,3 % (hysteresis and linearity
      ), ± 0,4 % (temperature influence from 0-50 °C)

      Functions: Tare function, Hold function, Min./Max. value memory, Serial interface, Power-Off-function, Peak value memory, Logger operation, averaging function, Min-/Max-alarm, Controlling function
      Scope of supply: 1 device, 1 battery, 1 manual

      Price info


      Product-ID: 600470

       
       


      Product Information
      Instruction Manual
      GMH 3161-002
      Feinest manometer for over/under pressure and pressure difference

      Description:
       
      with integrated absolute pressure sensor
      Suitable for air and non aggressive gas

      Specification:

      Measuring range: -5000 ... +500.0 Pa (-5.000 ... +5.000 mbar)
      Overlaod: max. 250 hPa (mbar)
      Accuracy (typ. values): ± 0,3 % (hysteresis and linearity), ± 0,4 % (temperature influence from 0-50 °C)
      Functions: Tare function, Hold function, Min./Max. value memory, Serial interface, Power-Off-function
      Scope of supply: 1 device, 1 battery, 1 manual

      Price info


      Product-ID: 600469

       
       
      «back [1] 2 3 forward»